Skip to content

parkkj/BONUS_GEMC

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

5 Commits
 
 
 
 
 
 

Repository files navigation

BONUS_GEMC

modular GEMC code for BONuS12 detector system with reconstruction code

####################################################################

README file may help you figure out problem that you are struggling....

####################################################################

1/ how to create bank structure into ROOT file ? [Solution] evio2root -B=bonus -WRITE_RAWS=No -INPUTF=bonus_gemc_out.evio => ROOT fiel contains the "xbonus" bank => You need to kill al other bank structure which are empty

2/ BONUS raw data: ADC energy deposition (charge integration) Time information (TDC) from GEM or GEM+WC [Q1] Need to know what/how integrate the proton deposit energy into ADC => Total energy loss during the track => Should be understood the eloss per step size (0.1mm or 0.5mm) => Given 0.1mm step size, We understood a straight track with eloss and produces a consistent result with Bethe-Bloch calculation

[Q2] where we get TDC info ? from 1st layer of wire chamber ? => Magboltz calculation gives you a electron drift velocity which interpereted to TDC

3/ Need a drift velocity information in term of gas mixture and pressure => Gail is calculating average.... => Impelemted the Magboltz calulation into GEMC (reproducible Jixie's result) [a] For now, only for single good track case... [b] For future, we need to implement multi-tracks

4/ Manipulate the B-field and E-field ?? possible...Do we need this ? [Q] Alternatively, we can have extra-step, which is MegaBolt code for drift time cal. => This is "3/" issue.

5/ How to stop tracking outside of BONUS => To avoid particle not back into detector again [Q] Why low momentum proton track is still passing through entire materials ? [Solution] When the geometry's created, it should be "mother=root" !! Then you see the track is trapped by even PCB...

6/ How to build the first layer of wire (geometry) in the BONUS.... [Q] Is this final design ? or even possible ? No.... [A] no need a further study....because there is a big dis-adventage for detecting lower momentum of proton (lost VIP)

7/ ROHACELL simulation.... (a) Need to figure what what material is .... [Solution] Actually, it is already defined in the BST material packages In addition, I copied the pc Board as well.

8/ hit_Process with ElectronTraport information from the MagBoltz (G. Dodge) a) Jixie has a draft version of G4 code implemting electron drift information. b) need to modify his code for GEMC....currently GEMC has integrated mode. -> need to seperated identifier CellID, PhiCellID, zCellID, .... -> no need to take into account multi hit from a single ionization point -> Jixie's minimum step size=0.07 cm ??? but why it is random ? These are resolved some point, please take a look at the Kijun's Bonus Wiki

====== Commnet: 12/02/2015 1/ changing the bonus_hitprocess.cc with MagBoltz electro drift transport formular and put the CellID at each ionization point. -> This make to be visiable red-dots at each ionization point in graphic interface

====== GEMC options:

gemc **.gcard -G4TRACK_VERBOSITY=1 : print out all tracks

====== 9/ There is a bug when I implemet Gasous D2 target in the cpp_material.cc that is one of the GEMC source files. [Problem] proton minimum momentum is 72MeV/c that is way high from Kuhn and Jixie simulation.... [Reason] the mMixHeGasD and mMixDMEGasD should have a dimensionless definition of density. [Solution] remove the "*mg/cm3" in line 73,74 Add "*kelvin" temperature unit in the line 81, 82

About