**     Method      :  AD1_OnMeasurementComplete (component ADC)
**
**     Description :
**         The method services the conversion complete interrupt of the 
**         selected peripheral(s) and eventually invokes the beans 
**         event(s).
**         This method is internal. It is used by Processor Expert only.
** ===================================================================
*/
void AdcLdd1_OnMeasurementComplete(LDD_TUserData *UserDataPtr)
{
  AdcLdd1_TResultData ResultData;      /* Temporary result data */
    
  (void)UserDataPtr;                   /* Parameter is not used, suppress unused argument warning */
  if (ModeFlg == CALIBRATING) {        /* If the driver is in CALIBRATING mode */
    (void)AdcLdd1_GetCalibrationResultStatus(AdcLdd1_DeviceDataPtr);
    ModeFlg = STOP;                    /* Set the device to the stop mode */
    AD1_OnCalibrationEnd();            /* If yes then invoke user event */
    return;                            /* Return from interrupt */
  }
  AdcLdd1_GetMeasuredValues(AdcLdd1_DeviceDataPtr, (LDD_TData *)&ResultData);
  AD1_OutV[SumChan] += ResultData;
  SumChan++;                           /* Increase counter of measured channels*/
  if (SumChan == 4U) {                 /* Is number of measured channels equal to the number of channels used in the component? */
    SumChan = 0U;                      /* If yes then set the counter of measured channels to 0 */
    SumCnt++;                          /* Increase counter of conversions*/
    if (SumCnt == 128U) {              /* Is number of conversions on each channel equal to the number of conversions defined in the component? */
      OutFlg = TRUE;                   /* Measured values are available */
      AD1_OnEnd();                     /* If yes then invoke user event */
      ModeFlg = STOP;                  /* Set the device to the stop mode */
      return;                          /* Return from interrupt */
    }
  }
  SampleGroup[0].ChannelIdx = SumChan; /* Start measurement of next channel */
  (void)AdcLdd1_CreateSampleGroup(AdcLdd1_DeviceDataPtr, (LDD_ADC_TSample *)SampleGroup, 1U); /* Configure sample group */
  (void)AdcLdd1_StartSingleMeasurement(AdcLdd1_DeviceDataPtr);
}
Beispiel #2
0
/*
** ===================================================================
**     Method      :  AD1_OnMeasurementComplete (component ADC)
**
**     Description :
**         The method services the conversion complete interrupt of the 
**         selected peripheral(s) and eventually invokes the beans 
**         event(s).
**         This method is internal. It is used by Processor Expert only.
** ===================================================================
*/
void AdcLdd1_OnMeasurementComplete(LDD_TUserData *UserDataPtr)
{
  (void)UserDataPtr;                   /* Parameter is not used, suppress unused argument warning */
  if (ModeFlg == STOP) {               /* If the driver is in STOP mode */
    return;                            /* Return from interrupt */
  }
  if (ModeFlg == CALIBRATING) {        /* If the driver is in CALIBRATING mode */
    (void)AdcLdd1_GetCalibrationResultStatus(AdcLdd1_DeviceDataPtr);
    ModeFlg = STOP;                    /* Set the device to the stop mode */
    AD1_OnCalibrationEnd();            /* If yes then invoke user event */
    return;                            /* Return from interrupt */
  }
  if (ModeFlg != SINGLE) {
    AdcLdd1_GetMeasuredValues(AdcLdd1_DeviceDataPtr, (LDD_TData *)&AD1_OutV);
    OutFlg = TRUE;                     /* Measured value is available */
    AD1_OnEnd();                       /* If yes then invoke user event */
    if (ModeFlg == MEASURE) {          /* Is the device in the measure state? */
      ModeFlg = STOP;                  /* Set the device to the stop mode */
      return;                          /* Return from interrupt */
    }
    SampleGroup[0].ChannelIdx = 0U;    /* Restart measurement */
    (void)AdcLdd1_CreateSampleGroup(AdcLdd1_DeviceDataPtr, (LDD_ADC_TSample *)SampleGroup, 1U); /* Configure sample group */
    (void)AdcLdd1_StartSingleMeasurement(AdcLdd1_DeviceDataPtr);
  }
  else {
    AdcLdd1_GetMeasuredValues(AdcLdd1_DeviceDataPtr, (LDD_TData *)&AD1_OutV);
    OutFlg = TRUE;                     /* Measured value is available */
    AD1_OnEnd();                       /* If yes then invoke user event */
    ModeFlg = STOP;                    /* Set the device to the stop mode */
  }
}
Beispiel #3
0
/*
** ===================================================================
**     Method      :  AD1_OnMeasurementComplete (component ADC)
**
**     Description :
**         The method services the conversion complete interrupt of the 
**         selected peripheral(s) and eventually invokes the beans 
**         event(s).
**         This method is internal. It is used by Processor Expert only.
** ===================================================================
*/
void AdcLdd1_OnMeasurementComplete(LDD_TUserData *UserDataPtr)
{
  (void)UserDataPtr;                   /* Parameter is not used, suppress unused argument warning */
  if (ModeFlg == CALIBRATING) {        /* If the driver is in CALIBRATING mode */
    (void)AdcLdd1_GetCalibrationResultStatus(AdcLdd1_DeviceDataPtr);
    ModeFlg = STOP;                    /* Set the device to the stop mode */
    AD1_OnCalibrationEnd();            /* If yes then invoke user event */
    return;                            /* Return from interrupt */
  }
  AdcLdd1_GetMeasuredValues(AdcLdd1_DeviceDataPtr, (LDD_TData *)&AD1_OutV);
  OutFlg = TRUE;                       /* Measured value is available */
  AD1_OnEnd();                         /* If yes then invoke user event */
  ModeFlg = STOP;                      /* Set the device to the stop mode */
}
Beispiel #4
0
/*
** ===================================================================
**     Method      :  AD1_Calibrate (component ADC)
**     Description :
**         This method starts self calibration process. Calibration is
**         typically used to remove the effects of the gain and offset
**         from a specific reading.
**     Parameters  :
**         NAME            - DESCRIPTION
**         WaitForResult   - Wait for a result of
**                           calibration. If the <interrupt service> is
**                           disabled, the WaitForResult parameter is
**                           ignored and the method waits for
**                           calibration result every time.
**     Returns     :
**         ---             - Error code
**                           ERR_OK - OK
**                           ERR_BUSY - A conversion is already running
**                           ERR_SPEED - This device does not work in
**                           the active speed mode
**                           ERR_DISABLED - Device is disabled
**                           ERR_FAILED - Calibration hasn't been
**                           finished correctly
** ===================================================================
*/
byte PE_AD1_Calibrate(void)
{
  if (ModeFlg != STOP) {               /* Is the device in different mode than "stop"? */
    return ERR_BUSY;                   /* If yes then error */
  }
  (void)AdcLdd1_GetMeasurementCompleteStatus(AdcLdd1_DeviceDataPtr); /* Clear measurement complete status */
  (void)AdcLdd1_StartCalibration(AdcLdd1_DeviceDataPtr); /* Start calibration */
  while (!AdcLdd1_GetMeasurementCompleteStatus(AdcLdd1_DeviceDataPtr)) {}; /* Wait until calibration ends */
  if (AdcLdd1_GetCalibrationResultStatus(AdcLdd1_DeviceDataPtr) != ERR_OK) { /* If calibration failed flag is set */
    ModeFlg = STOP;                    /* Set the device to the stop mode */
    return ERR_FAILED;                 /* Return ERR_FAILED error code */
  }
  return ERR_OK;                       /* ADC device is now calibrated */
}
Beispiel #5
0
/*
** ===================================================================
**     Method      :  AD1_Calibrate (component ADC)
**     Description :
**         This method starts self calibration process. Calibration is
**         typically used to remove the effects of the gain and offset
**         from a specific reading.
**     Parameters  :
**         NAME            - DESCRIPTION
**         WaitForResult   - Wait for a result of
**                           calibration. If the <interrupt service> is
**                           disabled, the WaitForResult parameter is
**                           ignored and the method waits for
**                           calibration result every time.
**     Returns     :
**         ---             - Error code
**                           ERR_OK - OK
**                           ERR_BUSY - A conversion is already running
**                           ERR_SPEED - This device does not work in
**                           the active speed mode
**                           ERR_DISABLED - Device is disabled
**                           ERR_FAILED - Calibration hasn't been
**                           finished correctly
** ===================================================================
*/
byte AD1_Calibrate(bool WaitForResult)
{
  if (ModeFlg != STOP) {               /* Is the device in different mode than "stop"? */
    return ERR_BUSY;                   /* If yes then error */
  }
  ModeFlg = CALIBRATING;               /* Set state of device to the calibration mode */
  (void)AdcLdd1_GetMeasurementCompleteStatus(AdcLdd1_DeviceDataPtr); /* Clear measurement complete status */
  (void)AdcLdd1_StartCalibration(AdcLdd1_DeviceDataPtr); /* Start calibration */
  if (!WaitForResult) {                /* If doesn't wait for result */
    return ERR_OK;                     /* then return ERR_OK, but user have to check the result of calibration e.g. by GetCalibrationStatus method */
  }
  while (!AdcLdd1_GetMeasurementCompleteStatus(AdcLdd1_DeviceDataPtr)) {}; /* Wait until calibration ends */
  if (AdcLdd1_GetCalibrationResultStatus(AdcLdd1_DeviceDataPtr) != ERR_OK) { /* If calibration failed flag is set */
    ModeFlg = STOP;                    /* Set the device to the stop mode */
    return ERR_FAILED;                 /* Return ERR_FAILED error code */
  }
  return ERR_OK;                       /* ADC device is now calibrated */
}