Beispiel #1
0
// reads register(s) from controller at address to len
// abel_comm_object_read(obj,"n7:90",4)
// will return a ABELDataReturn 
//   with type 0, len 4
//   with num of values at n7:90,n7:91,n7:92,n7:93
ABELDataReturn* abel_comm_object_read(ABELCommObject* obj,char* addr,int len)
{
    ABELDataReturn* out;
    out = abel_data_return_new();
	int type;
	type = abel_comm_object_get_device_type(obj);
	int x,sts,extsts;
	unsigned int temp1, temp2;
	struct _data data;
    out->len=len;
    obj->comm1.tns = obj->comm1.tns + 4;
	data=protread3(obj->comm1,addr,len,type,FALSE);
    if (data.len == -1)
		{
		sts = data.data[0];
		extsts = data.data[1];
		printf ("An error occured.  The PLC STS byte is %d, the EXT STS byte is %d\n",sts,extsts);
		if (sts != 0xf0)
			printf ("Primary Error code is %s\n",errors[(sts/16)]);
		if (extsts != 0)
			printf ("Extended error code is %s\n",ext_errors[extsts]);
		close (obj->comm1.handle);
		}
	switch (data.name.section)
		{
		case 0:
			if (data.name.floatdata == TRUE)
				{
				out->type=1;
				for (x=0;x<data.len;x=x+2)
					{
					temp1 = (data.data[x]);
					temp2 = (data.data[x+1]);
					out->flt[x]=itof(temp1,temp2);
					}
				}
			if (data.name.floatdata == FALSE)
				{
				out->type=0;
				for (x=0;x<(data.len);x++)
					out->num[x]=(int)data.data[x];
				}
			break;
		case 1:
		case 2:
		case 3:
		case 4:
		case 5:
		case 6:
		    for (x=0;x<data.len;x++)
				printf ("%02X  ",(byte)data.data[x]);
			printf ("\n");
		}	
  return out;
}
Beispiel #2
0
int main (int argc, char *argv[])
{
struct _comm comm;
struct _data data;
struct plc5stat status;
	int count,x,sts,extsts,type;
	unsigned int temp1, temp2;
	count=0;
	if (argc == 3)
		count = 1;
	if (argc == 4)
		count = atoi(argv[3]);
	if ((argc < 3) || (argc > 4))
		{
		printf ("\nThis program will read a register from an Ethernet connected Allen Bradley\n");
		printf ("PLC-5.  It should also work with a Pyramid Integrator.\n\n");
		printf ("Correct Usage:\nab <plc ip addr> <plc register> {<quantity>}\n");
		printf ("ab 192.168.10.5 n7:0   - will read one integer from N7:0 on plc 192.168.10.5\n");
		printf ("ab 192.168.10.5 n7:30 4 - will read four integers from N7:30 on plc 192.168.10.5\n"); 
		printf ("\n\n");
		exit (-1);
		}

	comm=abel_attach(argv[1],FALSE);
	if (comm.error != 0)
		{
		printf ("Could not connect.  Check your address and try again.\n");
		exit (-1);
		}
	status = getstatus (comm,FALSE);
	type = PLC5;
	if (status.type == 0xde)
		type = PLC5250;
	if (status.type == 0xee)
		type = SLC;
	comm.tns = comm.tns + 4;

	data=protread3(comm,argv[2],count,type,FALSE);
	if (data.len == -1)
		{
		sts = data.data[0];
		extsts = data.data[1];
		printf ("An error occured.  The PLC STS byte is %d, the EXT STS byte is %d\n",sts,extsts);
		if (sts != 0xf0)
			printf ("Primary Error code is %s\n",errors[(sts/16)]);
		if (extsts != 0)
			printf ("Extended error code is %s\n",ext_errors[extsts]);
		close (comm.handle);
		exit (-1);
		}
	switch (data.name.section)
		{
		case 0:
			if (data.name.floatdata == TRUE)
				{
				for (x=0;x<data.len;x=x+2)
					{
					temp1 = (data.data[x]);
					temp2 = (data.data[x+1]);
					printf ("%f\n",itof(temp1,temp2));
					}
				}
			if (data.name.floatdata == FALSE)
				{
				for (x=0;x<(data.len);x++)
					printf ("%d\n",(short)data.data[x]);
				}
			break;
		case 1:
		case 2:
		case 3:
		case 4:
		case 5:
		case 6:
			for (x=0;x<data.len;x++)
				printf ("%02X  ",(byte)data.data[x]);
			printf ("\n");
		}	 
	close (comm.handle);
	exit (0);
}