static int sec_fg_set_property(struct power_supply *psy,
			    enum power_supply_property psp,
			    const union power_supply_propval *val)
{
	struct sec_fuelgauge_info *fuelgauge =
		container_of(psy, struct sec_fuelgauge_info, psy_fg);
	sec_battery_platform_data_t *pdata = fuelgauge->pdata;

	switch (psp) {
	case POWER_SUPPLY_PROP_CHARGE_TYPE:
		if (!pdata->jig_irq)
			sec_hal_fg_set_property(fuelgauge->client, psp, val);
		break;
	case POWER_SUPPLY_PROP_STATUS:
		if (val->intval == POWER_SUPPLY_STATUS_FULL)
			sec_hal_fg_full_charged(fuelgauge->client);
		break;
	case POWER_SUPPLY_PROP_CHARGE_FULL:
		if (val->intval == POWER_SUPPLY_TYPE_BATTERY) {
			if (fuelgauge->pdata->capacity_calculation_type &
				SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE)
				sec_fg_calculate_dynamic_scale(fuelgauge);
		}
		break;
	case POWER_SUPPLY_PROP_ONLINE:
		fuelgauge->cable_type = val->intval;
		if (val->intval == POWER_SUPPLY_TYPE_BATTERY)
			fuelgauge->is_charging = false;
		else
			fuelgauge->is_charging = true;
		/* fall through */
	case POWER_SUPPLY_PROP_CAPACITY:
		if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_RESET) {
			fuelgauge->initial_update_of_soc = true;
			if (!sec_hal_fg_reset(fuelgauge->client))
				return -EINVAL;
			else
				break;
		}
	case POWER_SUPPLY_PROP_TEMP:
	case POWER_SUPPLY_PROP_TEMP_AMBIENT:
		if (!sec_hal_fg_set_property(fuelgauge->client, psp, val))
			return -EINVAL;
		break;
	default:
		return -EINVAL;
	}
	return 0;
}
static int sec_fg_set_property(struct power_supply *psy,
                               enum power_supply_property psp,
                               const union power_supply_propval *val)
{
    struct sec_fuelgauge_info *fuelgauge =
        container_of(psy, struct sec_fuelgauge_info, psy_fg);

    switch (psp) {
    case POWER_SUPPLY_PROP_STATUS:
        if (val->intval == POWER_SUPPLY_STATUS_FULL)
            sec_hal_fg_full_charged(fuelgauge->client);
        break;
    case POWER_SUPPLY_PROP_ONLINE:
        fuelgauge->cable_type = val->intval;
        if (val->intval == POWER_SUPPLY_TYPE_BATTERY)
            fuelgauge->is_charging = false;
        else
            fuelgauge->is_charging = true;
    case POWER_SUPPLY_PROP_CAPACITY:
        if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_RESET) {
            if (!sec_hal_fg_reset(fuelgauge->client))
                return -EINVAL;
            else
                break;
        }
    case POWER_SUPPLY_PROP_TEMP:
    case POWER_SUPPLY_PROP_TEMP_AMBIENT:
        if (!sec_hal_fg_set_property(fuelgauge->client, psp, val))
            return -EINVAL;
        break;
    default:
        return -EINVAL;
    }
    return 0;
}