static int do_calculate_time(int status, enum apm_source source)
{
	union power_supply_propval full;
	union power_supply_propval empty;
	union power_supply_propval cur;
	union power_supply_propval I;
	enum power_supply_property full_prop;
	enum power_supply_property full_design_prop;
	enum power_supply_property empty_prop;
	enum power_supply_property empty_design_prop;
	enum power_supply_property cur_avg_prop;
	enum power_supply_property cur_now_prop;

	if (MPSY_PROP(CURRENT_AVG, &I)) {
		/* if battery can't report average value, use momentary */
		if (MPSY_PROP(CURRENT_NOW, &I))
			return -1;
	}

	if (!I.intval)
		return 0;

	switch (source) {
	case SOURCE_CHARGE:
		full_prop = POWER_SUPPLY_PROP_CHARGE_FULL;
		full_design_prop = POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN;
		empty_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
		empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
		cur_avg_prop = POWER_SUPPLY_PROP_CHARGE_AVG;
		cur_now_prop = POWER_SUPPLY_PROP_CHARGE_NOW;
		break;
	case SOURCE_ENERGY:
		full_prop = POWER_SUPPLY_PROP_ENERGY_FULL;
		full_design_prop = POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN;
		empty_prop = POWER_SUPPLY_PROP_ENERGY_EMPTY;
		empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
		cur_avg_prop = POWER_SUPPLY_PROP_ENERGY_AVG;
		cur_now_prop = POWER_SUPPLY_PROP_ENERGY_NOW;
		break;
	case SOURCE_VOLTAGE:
		full_prop = POWER_SUPPLY_PROP_VOLTAGE_MAX;
		full_design_prop = POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN;
		empty_prop = POWER_SUPPLY_PROP_VOLTAGE_MIN;
		empty_design_prop = POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN;
		cur_avg_prop = POWER_SUPPLY_PROP_VOLTAGE_AVG;
		cur_now_prop = POWER_SUPPLY_PROP_VOLTAGE_NOW;
		break;
	default:
		printk(KERN_ERR "Unsupported source: %d\n", source);
		return -1;
	}

	if (_MPSY_PROP(full_prop, &full)) {
		/* if battery can't report this property, use design value */
		if (_MPSY_PROP(full_design_prop, &full))
			return -1;
	}

	if (_MPSY_PROP(empty_prop, &empty)) {
		/* if battery can't report this property, use design value */
		if (_MPSY_PROP(empty_design_prop, &empty))
			empty.intval = 0;
	}

	if (_MPSY_PROP(cur_avg_prop, &cur)) {
		/* if battery can't report average value, use momentary */
		if (_MPSY_PROP(cur_now_prop, &cur))
			return -1;
	}

	if (status == POWER_SUPPLY_STATUS_CHARGING)
		return ((cur.intval - full.intval) * 60L) / I.intval;
	else
		return -((cur.intval - empty.intval) * 60L) / I.intval;
}
Example #2
0
static void apm_battery_apm_get_power_status(struct apm_power_info *info)
{
	union power_supply_propval status;
	union power_supply_propval capacity, time_to_full, time_to_empty;

	mutex_lock(&apm_mutex);
	find_main_battery();
	if (!main_battery) {
		mutex_unlock(&apm_mutex);
		return;
	}

	/* status */

	if (MPSY_PROP(STATUS, &status))
		status.intval = POWER_SUPPLY_STATUS_UNKNOWN;

	/* ac line status */
#ifdef CONFIG_ARCH_BCM4760
	{
		union power_supply_propval online;

		MPSY_PROP(ONLINE, &online);
		if(online.intval){
			info->ac_line_status = APM_AC_ONLINE;
		} else {
			info->ac_line_status = APM_AC_OFFLINE;
		}
	}
#else
	if ((status.intval == POWER_SUPPLY_STATUS_CHARGING) ||
	    (status.intval == POWER_SUPPLY_STATUS_NOT_CHARGING) ||
	    (status.intval == POWER_SUPPLY_STATUS_FULL))
		info->ac_line_status = APM_AC_ONLINE;
	else
		info->ac_line_status = APM_AC_OFFLINE;
#endif
	/* battery life (i.e. capacity, in percents) */

	if (MPSY_PROP(CAPACITY, &capacity) == 0) {
		info->battery_life = capacity.intval;
	} else {
		/* try calculate using energy */
		info->battery_life = calculate_capacity(SOURCE_ENERGY);
		/* if failed try calculate using charge instead */
		if (info->battery_life == -1)
			info->battery_life = calculate_capacity(SOURCE_CHARGE);
		if (info->battery_life == -1)
			info->battery_life = calculate_capacity(SOURCE_VOLTAGE);
	}

	/* charging status */

	if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
		info->battery_status = APM_BATTERY_STATUS_CHARGING;
	} else {
		if (info->battery_life > 50)
			info->battery_status = APM_BATTERY_STATUS_HIGH;
		else if (info->battery_life > 5)
			info->battery_status = APM_BATTERY_STATUS_LOW;
		else
			info->battery_status = APM_BATTERY_STATUS_CRITICAL;
	}
	info->battery_flag = info->battery_status;

	/* time */

	info->units = APM_UNITS_MINS;

	if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
		if (!MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full) ||
				!MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full))
			info->time = time_to_full.intval / 60;
		else
			info->time = calculate_time(status.intval);
	} else {
		if (!MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty) ||
			      !MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty))
			info->time = time_to_empty.intval / 60;
		else
			info->time = calculate_time(status.intval);
	}

	mutex_unlock(&apm_mutex);
}
Example #3
0
static void apm_battery_apm_get_power_status(struct apm_power_info *info)
{
	union power_supply_propval status;
	union power_supply_propval capacity, time_to_full, time_to_empty;

	mutex_lock(&apm_mutex);
	find_main_battery();
	if (!main_battery) {
		mutex_unlock(&apm_mutex);
		return;
	}

	

	if (MPSY_PROP(STATUS, &status))
		status.intval = POWER_SUPPLY_STATUS_UNKNOWN;

	

	if ((status.intval == POWER_SUPPLY_STATUS_CHARGING) ||
	    (status.intval == POWER_SUPPLY_STATUS_NOT_CHARGING) ||
	    (status.intval == POWER_SUPPLY_STATUS_FULL))
		info->ac_line_status = APM_AC_ONLINE;
	else
		info->ac_line_status = APM_AC_OFFLINE;

	

	if (MPSY_PROP(CAPACITY, &capacity) == 0) {
		info->battery_life = capacity.intval;
	} else {
		
		info->battery_life = calculate_capacity(SOURCE_ENERGY);
		
		if (info->battery_life == -1)
			info->battery_life = calculate_capacity(SOURCE_CHARGE);
		if (info->battery_life == -1)
			info->battery_life = calculate_capacity(SOURCE_VOLTAGE);
	}

	

	if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
		info->battery_status = APM_BATTERY_STATUS_CHARGING;
	} else {
		if (info->battery_life > 50)
			info->battery_status = APM_BATTERY_STATUS_HIGH;
		else if (info->battery_life > 5)
			info->battery_status = APM_BATTERY_STATUS_LOW;
		else
			info->battery_status = APM_BATTERY_STATUS_CRITICAL;
	}
	info->battery_flag = info->battery_status;

	

	info->units = APM_UNITS_MINS;

	if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
		if (!MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full) ||
				!MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full))
			info->time = time_to_full.intval / 60;
		else
			info->time = calculate_time(status.intval);
	} else {
		if (!MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty) ||
			      !MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty))
			info->time = time_to_empty.intval / 60;
		else
			info->time = calculate_time(status.intval);
	}

	mutex_unlock(&apm_mutex);
}