Example #1
0
void measure(struct bme280_t * sens)
{
		s32 temp;
		bme280_read_uncomp_temperature(sens, &temp);
		s32 tempc = bme280_compensate_temperature_int32(sens, temp);
		transmit_decimal(tempc);

		bme280_read_uncomp_humidity(sens, &temp);
		tempc = bme280_compensate_humidity_int32(sens, temp);
		transmit_decimal(tempc>>10);
}
Example #2
0
OSStatus bme280_read_temperature(s32 *v_actual_temp_s32)
{
	s32 com_rslt = BME280_ERROR;  // result of communication results
	s32 v_data_uncomp_tem_s32 = BME280_INIT_VALUE;  // uncompensated temperature
     
        //-------------------------- NOTE ----------------------------------
        // this is to avoid i2c pin is re-init by other module because they use the same pin.
        MicoI2cInitialize(&user_i2c_device);
        //------------------------------------------------------------------
        
        com_rslt = bme280_read_uncomp_temperature(&v_data_uncomp_tem_s32);
         if(0 != com_rslt){
          return kReadErr;
        }
        
        *v_actual_temp_s32 = bme280_compensate_temperature_int32(v_data_uncomp_tem_s32);
        
        return kNoErr;
}
Example #3
0
/* This function is an example for reading sensor data
 *	\param: None
 *	\return: communication result
 */
s32 bme280_data_readout_template(void)
{
	/* The variable used to assign the standby time*/
	u8 v_stand_by_time_u8 = BME280_INIT_VALUE;
	/* The variable used to read uncompensated temperature*/
	s32 v_data_uncomp_tem_s32 = BME280_INIT_VALUE;
	/* The variable used to read uncompensated pressure*/
	s32 v_data_uncomp_pres_s32 = BME280_INIT_VALUE;
	/* The variable used to read uncompensated pressure*/
	s32 v_data_uncomp_hum_s32 = BME280_INIT_VALUE;
	/* The variable used to read real temperature*/
	s32 v_actual_temp_s32 = BME280_INIT_VALUE;
	/* The variable used to read real pressure*/
	u32 v_actual_press_u32 = BME280_INIT_VALUE;
	/* The variable used to read real humidity*/
	u32 v_actual_humity_u32 = BME280_INIT_VALUE;
	/* result of communication results*/
	s32 com_rslt = BME280_ERROR;



 /*********************** START INITIALIZATION ************************/
  /*	Based on the user need configure I2C or SPI interface.
  *	It is example code to explain how to use the bme280 API*/
  #ifdef BME280_API
	I2C_routine();
	/*SPI_routine(); */
	#endif
/*--------------------------------------------------------------------------*
 *  This function used to assign the value/reference of
 *	the following parameters
 *	I2C address
 *	Bus Write
 *	Bus read
 *	Chip id
*-------------------------------------------------------------------------*/
	com_rslt = bme280_init(&bme280);

	/*	For initialization it is required to set the mode of
	 *	the sensor as "NORMAL"
	 *	data acquisition/read/write is possible in this mode
	 *	by using the below API able to set the power mode as NORMAL*/
	/* Set the power mode as NORMAL*/
	com_rslt += bme280_set_power_mode(BME280_NORMAL_MODE);
	/*	For reading the pressure, humidity and temperature data it is required to
	 *	set the OSS setting of humidity, pressure and temperature
	 * The "BME280_CTRLHUM_REG_OSRSH" register sets the humidity
	 * data acquisition options of the device.
	 * changes to this registers only become effective after a write operation to
	 * "BME280_CTRLMEAS_REG" register.
	 * In the code automated reading and writing of "BME280_CTRLHUM_REG_OSRSH"
	 * register first set the "BME280_CTRLHUM_REG_OSRSH" and then read and write
	 * the "BME280_CTRLMEAS_REG" register in the function*/
	com_rslt += bme280_set_oversamp_humidity(BME280_OVERSAMP_1X);

	/* set the pressure oversampling*/
	com_rslt += bme280_set_oversamp_pressure(BME280_OVERSAMP_2X);
	/* set the temperature oversampling*/
	com_rslt += bme280_set_oversamp_temperature(BME280_OVERSAMP_4X);
/*--------------------------------------------------------------------------*/
/*------------------------------------------------------------------------*
************************* START GET and SET FUNCTIONS DATA ****************
*---------------------------------------------------------------------------*/
	/* This API used to Write the standby time of the sensor input
	 *	value have to be given
	 *	Normal mode comprises an automated perpetual cycling between an (active)
	 *	Measurement period and an (inactive) standby period.
	 *	The standby time is determined by the contents of the register t_sb.
	 *	Standby time can be set using BME280_STANDBYTIME_125_MS.
	 *	Usage Hint : bme280_set_standbydur(BME280_STANDBYTIME_125_MS)*/

	com_rslt += bme280_set_standby_durn(BME280_STANDBY_TIME_1_MS);

	/* This API used to read back the written value of standby time*/
	com_rslt += bme280_get_standby_durn(&v_stand_by_time_u8);
/*-----------------------------------------------------------------*
************************* END GET and SET FUNCTIONS ****************
*------------------------------------------------------------------*/

/************************* END INITIALIZATION *************************/

/*------------------------------------------------------------------*
************ START READ UNCOMPENSATED PRESSURE, TEMPERATURE
AND HUMIDITY DATA ********
*---------------------------------------------------------------------*/
	/* API is used to read the uncompensated temperature*/
	com_rslt += bme280_read_uncomp_temperature(&v_data_uncomp_tem_s32);

	/* API is used to read the uncompensated pressure*/
	com_rslt += bme280_read_uncomp_pressure(&v_data_uncomp_pres_s32);

	/* API is used to read the uncompensated humidity*/
	com_rslt += bme280_read_uncomp_humidity(&v_data_uncomp_hum_s32);

	/* API is used to read the uncompensated temperature,pressure
	and humidity data */
	com_rslt += bme280_read_uncomp_pressure_temperature_humidity(
	&v_data_uncomp_tem_s32, &v_data_uncomp_pres_s32, &v_data_uncomp_hum_s32);
/*--------------------------------------------------------------------*
************ END READ UNCOMPENSATED PRESSURE AND TEMPERATURE********
*-------------------------------------------------------------------------*/

/*------------------------------------------------------------------*
************ START READ TRUE PRESSURE, TEMPERATURE
AND HUMIDITY DATA ********
*---------------------------------------------------------------------*/
	/* API is used to read the true temperature*/
	/* Input value as uncompensated temperature and output format*/
	com_rslt += bme280_compensate_temperature_int32(v_data_uncomp_tem_s32);

	/* API is used to read the true pressure*/
	/* Input value as uncompensated pressure */
	com_rslt += bme280_compensate_pressure_int32(v_data_uncomp_pres_s32);

	/* API is used to read the true humidity*/
	/* Input value as uncompensated humidity and output format*/
	com_rslt += bme280_compensate_humidity_int32(v_data_uncomp_hum_s32);

	/* API is used to read the true temperature, humidity and pressure*/
	com_rslt += bme280_read_pressure_temperature_humidity(
	&v_actual_press_u32, &v_actual_temp_s32, &v_actual_humity_u32);
/*--------------------------------------------------------------------*
************ END READ TRUE PRESSURE, TEMPERATURE AND HUMIDITY ********
*-------------------------------------------------------------------------*/

/*-----------------------------------------------------------------------*
************************* START DE-INITIALIZATION ***********************
*-------------------------------------------------------------------------*/
	/*	For de-initialization it is required to set the mode of
	 *	the sensor as "SLEEP"
	 *	the device reaches the lowest power consumption only
	 *	In SLEEP mode no measurements are performed
	 *	All registers are accessible
	 *	by using the below API able to set the power mode as SLEEP*/
	 /* Set the power mode as SLEEP*/
	com_rslt += bme280_set_power_mode(BME280_SLEEP_MODE);
/*---------------------------------------------------------------------*
************************* END DE-INITIALIZATION **********************
*---------------------------------------------------------------------*/