Example #1
0
static bool tegra_sdhci_is_pad_and_regulator_valid(struct sdhci_host *host)
{
	struct sdhci_pltfm_host *pltfm_host = sdhci_priv(host);
	struct sdhci_tegra *tegra_host = sdhci_pltfm_priv(pltfm_host);
	int has_1v8, has_3v3;

	/*
	 * The SoCs which have NVQUIRK_NEEDS_PAD_CONTROL require software pad
	 * voltage configuration in order to perform voltage switching. This
	 * means that valid pinctrl info is required on SDHCI instances capable
	 * of performing voltage switching. Whether or not an SDHCI instance is
	 * capable of voltage switching is determined based on the regulator.
	 */

	if (!(tegra_host->soc_data->nvquirks & NVQUIRK_NEEDS_PAD_CONTROL))
		return true;

	if (IS_ERR(host->mmc->supply.vqmmc))
		return false;

	has_1v8 = regulator_is_supported_voltage(host->mmc->supply.vqmmc,
						 1700000, 1950000);

	has_3v3 = regulator_is_supported_voltage(host->mmc->supply.vqmmc,
						 2700000, 3600000);

	if (has_1v8 == 1 && has_3v3 == 1)
		return tegra_host->pad_control_available;

	/* Fixed voltage, no pad control required. */
	return true;
}
Example #2
0
static int cpufreq_init(struct cpufreq_policy *policy)
{
	struct cpufreq_dt_platform_data *pd;
	struct cpufreq_frequency_table *freq_table;
	struct thermal_cooling_device *cdev;
	struct device_node *np;
	struct private_data *priv;
	struct device *cpu_dev;
	struct regulator *cpu_reg;
	struct clk *cpu_clk;
	unsigned long min_uV = ~0, max_uV = 0;
	unsigned int transition_latency;
	int ret;

	ret = allocate_resources(policy->cpu, &cpu_dev, &cpu_reg, &cpu_clk);
	if (ret) {
		pr_err("%s: Failed to allocate resources\n: %d", __func__, ret);
		return ret;
	}

	np = of_node_get(cpu_dev->of_node);
	if (!np) {
		dev_err(cpu_dev, "failed to find cpu%d node\n", policy->cpu);
		ret = -ENOENT;
		goto out_put_reg_clk;
	}

	/* OPPs might be populated at runtime, don't check for error here */
	of_init_opp_table(cpu_dev);

	priv = kzalloc(sizeof(*priv), GFP_KERNEL);
	if (!priv) {
		ret = -ENOMEM;
		goto out_put_node;
	}

	of_property_read_u32(np, "voltage-tolerance", &priv->voltage_tolerance);

	if (of_property_read_u32(np, "clock-latency", &transition_latency))
		transition_latency = CPUFREQ_ETERNAL;

	if (!IS_ERR(cpu_reg)) {
		unsigned long opp_freq = 0;

		/*
		 * Disable any OPPs where the connected regulator isn't able to
		 * provide the specified voltage and record minimum and maximum
		 * voltage levels.
		 */
		while (1) {
			struct dev_pm_opp *opp;
			unsigned long opp_uV, tol_uV;

			rcu_read_lock();
			opp = dev_pm_opp_find_freq_ceil(cpu_dev, &opp_freq);
			if (IS_ERR(opp)) {
				rcu_read_unlock();
				break;
			}
			opp_uV = dev_pm_opp_get_voltage(opp);
			rcu_read_unlock();

			tol_uV = opp_uV * priv->voltage_tolerance / 100;
			if (regulator_is_supported_voltage(cpu_reg, opp_uV,
							   opp_uV + tol_uV)) {
				if (opp_uV < min_uV)
					min_uV = opp_uV;
				if (opp_uV > max_uV)
					max_uV = opp_uV;
			} else {
				dev_pm_opp_disable(cpu_dev, opp_freq);
			}

			opp_freq++;
		}

		ret = regulator_set_voltage_time(cpu_reg, min_uV, max_uV);
		if (ret > 0)
			transition_latency += ret * 1000;
	}

	ret = dev_pm_opp_init_cpufreq_table(cpu_dev, &freq_table);
	if (ret) {
		pr_err("failed to init cpufreq table: %d\n", ret);
		goto out_free_priv;
	}

	/*
	 * For now, just loading the cooling device;
	 * thermal DT code takes care of matching them.
	 */
	if (of_find_property(np, "#cooling-cells", NULL)) {
		cdev = of_cpufreq_cooling_register(np, cpu_present_mask);
		if (IS_ERR(cdev))
			dev_err(cpu_dev,
				"running cpufreq without cooling device: %ld\n",
				PTR_ERR(cdev));
		else
			priv->cdev = cdev;
	}

	priv->cpu_dev = cpu_dev;
	priv->cpu_reg = cpu_reg;
	policy->driver_data = priv;

	policy->clk = cpu_clk;
	ret = cpufreq_table_validate_and_show(policy, freq_table);
	if (ret) {
		dev_err(cpu_dev, "%s: invalid frequency table: %d\n", __func__,
			ret);
		goto out_cooling_unregister;
	}

	policy->cpuinfo.transition_latency = transition_latency;

	pd = cpufreq_get_driver_data();
	if (!pd || !pd->independent_clocks)
		cpumask_setall(policy->cpus);

	of_node_put(np);

	return 0;

out_cooling_unregister:
	cpufreq_cooling_unregister(priv->cdev);
	dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
out_free_priv:
	kfree(priv);
out_put_node:
	of_node_put(np);
out_put_reg_clk:
	clk_put(cpu_clk);
	if (!IS_ERR(cpu_reg))
		regulator_put(cpu_reg);

	return ret;
}