Esempio n. 1
0
int fdtdec_get_chosen_node(const void *blob, const char *name)
{
	const char *prop;

	prop = fdtdec_get_chosen_prop(blob, name);
	if (!prop)
		return -FDT_ERR_NOTFOUND;
	return fdt_path_offset(blob, prop);
}
Esempio n. 2
0
static int serial_check_stdout(const void *blob, struct udevice **devp)
{
	int node;

	/* Check for a chosen console */
	node = fdtdec_get_chosen_node(blob, "stdout-path");
	if (node < 0) {
		const char *str, *p, *name;

		/*
		 * Deal with things like
		 *	stdout-path = "serial0:115200n8";
		 *
		 * We need to look up the alias and then follow it to the
		 * correct node.
		 */
		str = fdtdec_get_chosen_prop(blob, "stdout-path");
		if (str) {
			p = strchr(str, ':');
			name = fdt_get_alias_namelen(blob, str,
					p ? p - str : strlen(str));
			if (name)
				node = fdt_path_offset(blob, name);
		}
	}
	if (node < 0)
		node = fdt_path_offset(blob, "console");
	if (!uclass_get_device_by_of_offset(UCLASS_SERIAL, node, devp))
		return 0;

	/*
	 * If the console is not marked to be bound before relocation, bind it
	 * anyway.
	 */
	if (node > 0 && !lists_bind_fdt(gd->dm_root, offset_to_ofnode(node),
					devp)) {
		if (!device_probe(*devp))
			return 0;
	}

	return -ENODEV;
}
Esempio n. 3
0
static void serial_find_console_or_panic(void)
{
	const void *blob = gd->fdt_blob;
	struct udevice *dev;
	int node;

	if (CONFIG_IS_ENABLED(OF_CONTROL) && blob) {
		/* Check for a chosen console */
		node = fdtdec_get_chosen_node(blob, "stdout-path");
		if (node < 0) {
			const char *str, *p, *name;

			/*
			 * Deal with things like
			 *	stdout-path = "serial0:115200n8";
			 *
			 * We need to look up the alias and then follow it to
			 * the correct node.
			 */
			str = fdtdec_get_chosen_prop(blob, "stdout-path");
			if (str) {
				p = strchr(str, ':');
				name = fdt_get_alias_namelen(blob, str,
						p ? p - str : strlen(str));
				if (name)
					node = fdt_path_offset(blob, name);
			}
		}
		if (node < 0)
			node = fdt_path_offset(blob, "console");
		if (!uclass_get_device_by_of_offset(UCLASS_SERIAL, node,
						    &dev)) {
			gd->cur_serial_dev = dev;
			return;
		}

		/*
		* If the console is not marked to be bound before relocation,
		* bind it anyway.
		*/
		if (node > 0 &&
		    !lists_bind_fdt(gd->dm_root, blob, node, &dev)) {
			if (!device_probe(dev)) {
				gd->cur_serial_dev = dev;
				return;
			}
		}
	}
	if (!SPL_BUILD || !CONFIG_IS_ENABLED(OF_CONTROL) || !blob) {
		/*
		* Try to use CONFIG_CONS_INDEX if available (it is numbered
		* from 1!).
		*
		* Failing that, get the device with sequence number 0, or in
		* extremis just the first serial device we can find. But we
		* insist on having a console (even if it is silent).
		*/
#ifdef CONFIG_CONS_INDEX
#define INDEX (CONFIG_CONS_INDEX - 1)
#else
#define INDEX 0
#endif
		if (!uclass_get_device_by_seq(UCLASS_SERIAL, INDEX, &dev) ||
		    !uclass_get_device(UCLASS_SERIAL, INDEX, &dev) ||
		    (!uclass_first_device(UCLASS_SERIAL, &dev) && dev)) {
			gd->cur_serial_dev = dev;
			return;
		}
#undef INDEX
	}

#ifdef CONFIG_REQUIRE_SERIAL_CONSOLE
	panic_str("No serial driver found");
#endif
}