Esempio n. 1
0
int compat_setup_rt_frame(int sig, struct k_sigaction *ka, siginfo_t *info,
			  sigset_t *set, struct pt_regs *regs)
{
	unsigned long restorer;
	struct compat_rt_sigframe __user *frame;
	int err = 0;
	int usig;

	frame = compat_get_sigframe(ka, regs, sizeof(*frame));

	if (!access_ok(VERIFY_WRITE, frame, sizeof(*frame)))
		goto give_sigsegv;

	usig = current_thread_info()->exec_domain
		&& current_thread_info()->exec_domain->signal_invmap
		&& sig < 32
		? current_thread_info()->exec_domain->signal_invmap[sig]
		: sig;

	/* Always write at least the signal number for the stack backtracer. */
	if (ka->sa.sa_flags & SA_SIGINFO) {
		/* At sigreturn time, restore the callee-save registers too. */
		err |= copy_siginfo_to_user32(&frame->info, info);
		regs->flags |= PT_FLAGS_RESTORE_REGS;
	} else {
		err |= __put_user(info->si_signo, &frame->info.si_signo);
	}

	/* Create the ucontext.  */
	err |= __clear_user(&frame->save_area, sizeof(frame->save_area));
	err |= __put_user(0, &frame->uc.uc_flags);
	err |= __put_user(0, &frame->uc.uc_link);
	err |= __put_user(ptr_to_compat((void *)(current->sas_ss_sp)),
			  &frame->uc.uc_stack.ss_sp);
	err |= __put_user(sas_ss_flags(regs->sp),
			  &frame->uc.uc_stack.ss_flags);
	err |= __put_user(current->sas_ss_size, &frame->uc.uc_stack.ss_size);
	err |= setup_sigcontext(&frame->uc.uc_mcontext, regs);
	err |= __copy_to_user(&frame->uc.uc_sigmask, set, sizeof(*set));
	if (err)
		goto give_sigsegv;

	restorer = VDSO_BASE;
	if (ka->sa.sa_flags & SA_RESTORER)
		restorer = ptr_to_compat_reg(ka->sa.sa_restorer);

	/*
	 * Set up registers for signal handler.
	 * Registers that we don't modify keep the value they had from
	 * user-space at the time we took the signal.
	 */
	regs->pc = ptr_to_compat_reg(ka->sa.sa_handler);
	regs->ex1 = PL_ICS_EX1(USER_PL, 1); /* set crit sec in handler */
	regs->sp = ptr_to_compat_reg(frame);
	regs->lr = restorer;
	regs->regs[0] = (unsigned long) usig;

	if (ka->sa.sa_flags & SA_SIGINFO) {
		/* Need extra arguments, so mark to restore caller-saves. */
		regs->regs[1] = ptr_to_compat_reg(&frame->info);
		regs->regs[2] = ptr_to_compat_reg(&frame->uc);
		regs->flags |= PT_FLAGS_CALLER_SAVES;
	}

	/*
	 * Notify any tracer that was single-stepping it.
	 * The tracer may want to single-step inside the
	 * handler too.
	 */
	if (test_thread_flag(TIF_SINGLESTEP))
		ptrace_notify(SIGTRAP);

	return 0;

give_sigsegv:
	force_sigsegv(sig, current);
	return -EFAULT;
}
int compat_setup_rt_frame(int sig, struct k_sigaction *ka, siginfo_t *info,
			  sigset_t *set, struct pt_regs *regs)
{
	unsigned long restorer;
	struct compat_rt_sigframe __user *frame;
	int err = 0;
	int usig;

	frame = compat_get_sigframe(ka, regs, sizeof(*frame));

	if (!access_ok(VERIFY_WRITE, frame, sizeof(*frame)))
		goto give_sigsegv;

	usig = current_thread_info()->exec_domain
		&& current_thread_info()->exec_domain->signal_invmap
		&& sig < 32
		? current_thread_info()->exec_domain->signal_invmap[sig]
		: sig;

	
	if (ka->sa.sa_flags & SA_SIGINFO) {
		
		err |= copy_siginfo_to_user32(&frame->info, info);
		regs->flags |= PT_FLAGS_RESTORE_REGS;
	} else {
		err |= __put_user(info->si_signo, &frame->info.si_signo);
	}

	
	err |= __clear_user(&frame->save_area, sizeof(frame->save_area));
	err |= __put_user(0, &frame->uc.uc_flags);
	err |= __put_user(0, &frame->uc.uc_link);
	err |= __put_user(ptr_to_compat((void *)(current->sas_ss_sp)),
			  &frame->uc.uc_stack.ss_sp);
	err |= __put_user(sas_ss_flags(regs->sp),
			  &frame->uc.uc_stack.ss_flags);
	err |= __put_user(current->sas_ss_size, &frame->uc.uc_stack.ss_size);
	err |= setup_sigcontext(&frame->uc.uc_mcontext, regs);
	err |= __copy_to_user(&frame->uc.uc_sigmask, set, sizeof(*set));
	if (err)
		goto give_sigsegv;

	restorer = VDSO_BASE;
	if (ka->sa.sa_flags & SA_RESTORER)
		restorer = ptr_to_compat_reg(ka->sa.sa_restorer);

	regs->pc = ptr_to_compat_reg(ka->sa.sa_handler);
	regs->ex1 = PL_ICS_EX1(USER_PL, 1); 
	regs->sp = ptr_to_compat_reg(frame);
	regs->lr = restorer;
	regs->regs[0] = (unsigned long) usig;
	regs->regs[1] = ptr_to_compat_reg(&frame->info);
	regs->regs[2] = ptr_to_compat_reg(&frame->uc);
	regs->flags |= PT_FLAGS_CALLER_SAVES;

	if (test_thread_flag(TIF_SINGLESTEP))
		ptrace_notify(SIGTRAP);

	return 0;

give_sigsegv:
	signal_fault("bad setup frame", regs, frame, sig);
	return -EFAULT;
}
Esempio n. 3
0
int compat_setup_rt_frame(int sig, struct k_sigaction *ka, siginfo_t *info,
			  sigset_t *set, struct pt_regs *regs)
{
	unsigned long restorer;
	struct compat_rt_sigframe __user *frame;
	int err = 0;
	int usig;

	frame = compat_get_sigframe(ka, regs, sizeof(*frame));

	if (!access_ok(VERIFY_WRITE, frame, sizeof(*frame)))
		goto give_sigsegv;

	usig = current_thread_info()->exec_domain
		&& current_thread_info()->exec_domain->signal_invmap
		&& sig < 32
		? current_thread_info()->exec_domain->signal_invmap[sig]
		: sig;

	/* Always write at least the signal number for the stack backtracer. */
	if (ka->sa.sa_flags & SA_SIGINFO) {
		/* At sigreturn time, restore the callee-save registers too. */
		err |= copy_siginfo_to_user32(&frame->info, info);
		regs->flags |= PT_FLAGS_RESTORE_REGS;
	} else {
		err |= __put_user(info->si_signo, &frame->info.si_signo);
	}

	/* Create the ucontext.  */
	err |= __clear_user(&frame->save_area, sizeof(frame->save_area));
	err |= __put_user(0, &frame->uc.uc_flags);
	err |= __put_user(0, &frame->uc.uc_link);
	err |= __put_user(ptr_to_compat((void *)(current->sas_ss_sp)),
			  &frame->uc.uc_stack.ss_sp);
	err |= __put_user(sas_ss_flags(regs->sp),
			  &frame->uc.uc_stack.ss_flags);
	err |= __put_user(current->sas_ss_size, &frame->uc.uc_stack.ss_size);
	err |= setup_sigcontext(&frame->uc.uc_mcontext, regs);
	err |= __copy_to_user(&frame->uc.uc_sigmask, set, sizeof(*set));
	if (err)
		goto give_sigsegv;

	restorer = VDSO_BASE;
	if (ka->sa.sa_flags & SA_RESTORER)
		restorer = ptr_to_compat_reg(ka->sa.sa_restorer);

	/*
	 * Set up registers for signal handler.
	 * Registers that we don't modify keep the value they had from
	 * user-space at the time we took the signal.
	 * We always pass siginfo and mcontext, regardless of SA_SIGINFO,
	 * since some things rely on this (e.g. glibc's debug/segfault.c).
	 */
	regs->pc = ptr_to_compat_reg(ka->sa.sa_handler);
	regs->ex1 = PL_ICS_EX1(USER_PL, 1); /* set crit sec in handler */
	regs->sp = ptr_to_compat_reg(frame);
	regs->lr = restorer;
	regs->regs[0] = (unsigned long) usig;
	regs->regs[1] = ptr_to_compat_reg(&frame->info);
	regs->regs[2] = ptr_to_compat_reg(&frame->uc);
	regs->flags |= PT_FLAGS_CALLER_SAVES;
	return 0;

give_sigsegv:
	signal_fault("bad setup frame", regs, frame, sig);
	return -EFAULT;
}