/*! \brief Example application entry function.
 */
touch_ret_t touch_sensors_init(void)
{
	touch_ret_t touch_ret = TOUCH_SUCCESS;

	/* Setup and enable generic clock source for PTC module. */
	touch_configure_ptc_clock();

	touch_time.measurement_period_ms = DEF_TOUCH_MEASUREMENT_PERIOD_MS;

	/* Initialize touch library for Mutual Cap operation. */
	touch_ret = touch_mutlcap_sensors_init(&touch_config);
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

#if DEF_TOUCH_QDEBUG_ENABLE == 1
	QDebug_Init();
#endif

	/* configure the touch library sensors. */
	touch_ret = touch_sensors_config();
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

	touch_ret = touch_mutlcap_sensors_calibrate();
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

	return (touch_ret);
}
Пример #2
0
/*! \brief Example application entry function.
 */
touch_ret_t touch_sensors_init(void)
{
	touch_ret_t touch_ret = TOUCH_SUCCESS;

	/* Setup and enable generic clock source for PTC module. */
	touch_configure_ptc_clock();

	touch_time.measurement_period_ms = DEF_TOUCH_MEASUREMENT_PERIOD_MS;

	/* Initialize touch library for Mutual Cap operation. */
	touch_ret = touch_mutlcap_sensors_init(&touch_config);
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

#if DEF_TOUCH_QDEBUG_ENABLE == 1
	QDebug_Init();
#endif

	/* configure the touch library sensors. */
	touch_ret = touch_sensors_config();
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

	/* Auto Tuning setting for calibration.
	 *
	 * AUTO_TUNE_PRSC: When Auto tuning of pre-scaler is selected
	 * the PTC uses the user defined internal series resistor setting
	 * (DEF_MUTLCAP_SENSE_RESISTOR) and the pre-scaler is adjusted
	 * to slow down the PTC operation to ensure full charge transfer.
	 *
	 * AUTO_TUNE_RSEL: When Auto tuning of the series resistor is
	 * selected the PTC runs at user defined pre-scaler setting speed
	 * (DEF_MUTLCAP_CLK_PRESCALE) and the internal series resistor is
	 * tuned automatically to the optimum value to allow for full
	 * charge transfer.
	 *
	 * AUTO_TUNE_NONE: When manual tuning option is selected (AUTO_TUNE_NONE),
	 * the user defined values of PTC pre-scaler and series resistor is used
	 * for PTC operation as given in DEF_MUTLCAP_CLK_PRESCALE and
	 * DEF_MUTLCAP_SENSE_RESISTOR
	 *
	 */
	touch_ret = touch_mutlcap_sensors_calibrate(AUTO_TUNE_RSEL);
	if (touch_ret != TOUCH_SUCCESS) {
		while (1u) {    /* Check API Error return code. */
		}
	}

	return (touch_ret);
}