 * eeh_slot_error_detail - Generate combined log including driver log and error log
 * @pe: EEH PE
 * @severity: temporary or permanent error log
 *
 * This routine should be called to generate the combined log, which
 * is comprised of driver log and error log. The driver log is figured
 * out from the config space of the corresponding PCI device, while
 * the error log is fetched through platform dependent function call.
 */
void eeh_slot_error_detail(struct eeh_pe *pe, int severity)
{
	size_t loglen = 0;
	struct eeh_dev *edev, *tmp;

	/*
	 * When the PHB is fenced or dead, it's pointless to collect
	 * the data from PCI config space because it should return
	 * 0xFF's. For ER, we still retrieve the data from the PCI
	 * config space.
	 *
	 * For pHyp, we have to enable IO for log retrieval. Otherwise,
	 * 0xFF's is always returned from PCI config space.
	 */
	if (!(pe->type & EEH_PE_PHB)) {
		if (eeh_has_flag(EEH_ENABLE_IO_FOR_LOG))
			eeh_pci_enable(pe, EEH_OPT_THAW_MMIO);
		eeh_ops->configure_bridge(pe);
		eeh_pe_restore_bars(pe);

		pci_regs_buf[0] = 0;
		eeh_pe_for_each_dev(pe, edev, tmp) {
			loglen += eeh_gather_pci_data(edev, pci_regs_buf + loglen,
						      EEH_PCI_REGS_LOG_LEN - loglen);
		}
	}
示例#2
0
/*
 * Explicitly clear PE's frozen state for PowerNV where
 * we have frozen PE until BAR restore is completed. It's
 * harmless to clear it for pSeries. To be consistent with
 * PE reset (for 3 times), we try to clear the frozen state
 * for 3 times as well.
 */
static void *__eeh_clear_pe_frozen_state(void *data, void *flag)
{
	struct eeh_pe *pe = (struct eeh_pe *)data;
	int i, rc;

	for (i = 0; i < 3; i++) {
		rc = eeh_pci_enable(pe, EEH_OPT_THAW_MMIO);
		if (rc)
			continue;
		rc = eeh_pci_enable(pe, EEH_OPT_THAW_DMA);
		if (!rc)
			break;
	}

	/* The PE has been isolated, clear it */
	if (rc) {
		pr_warn("%s: Can't clear frozen PHB#%x-PE#%x (%d)\n",
			__func__, pe->phb->global_number, pe->addr, rc);
		return (void *)pe;
	}

	return NULL;
}
示例#3
0
/**
 * eeh_slot_error_detail - Generate combined log including driver log and error log
 * @pe: EEH PE
 * @severity: temporary or permanent error log
 *
 * This routine should be called to generate the combined log, which
 * is comprised of driver log and error log. The driver log is figured
 * out from the config space of the corresponding PCI device, while
 * the error log is fetched through platform dependent function call.
 */
void eeh_slot_error_detail(struct eeh_pe *pe, int severity)
{
	size_t loglen = 0;

	/*
	 * When the PHB is fenced or dead, it's pointless to collect
	 * the data from PCI config space because it should return
	 * 0xFF's. For ER, we still retrieve the data from the PCI
	 * config space.
	 *
	 * For pHyp, we have to enable IO for log retrieval. Otherwise,
	 * 0xFF's is always returned from PCI config space.
	 */
	if (!(pe->type & EEH_PE_PHB)) {
		if (eeh_has_flag(EEH_ENABLE_IO_FOR_LOG))
			eeh_pci_enable(pe, EEH_OPT_THAW_MMIO);

		/*
		 * The config space of some PCI devices can't be accessed
		 * when their PEs are in frozen state. Otherwise, fenced
		 * PHB might be seen. Those PEs are identified with flag
		 * EEH_PE_CFG_RESTRICTED, indicating EEH_PE_CFG_BLOCKED
		 * is set automatically when the PE is put to EEH_PE_ISOLATED.
		 *
		 * Restoring BARs possibly triggers PCI config access in
		 * (OPAL) firmware and then causes fenced PHB. If the
		 * PCI config is blocked with flag EEH_PE_CFG_BLOCKED, it's
		 * pointless to restore BARs and dump config space.
		 */
		eeh_ops->configure_bridge(pe);
		if (!(pe->state & EEH_PE_CFG_BLOCKED)) {
			eeh_pe_restore_bars(pe);

			pci_regs_buf[0] = 0;
			eeh_pe_traverse(pe, eeh_dump_pe_log, &loglen);
		}
	}

	eeh_ops->get_log(pe, severity, pci_regs_buf, loglen);
}
示例#4
0
struct eeh_dev *handle_eeh_events(struct eeh_event *event)
{
	struct device_node *frozen_dn;
	struct eeh_dev *frozen_edev;
	struct pci_bus *frozen_bus;
	int rc = 0;
	enum pci_ers_result result = PCI_ERS_RESULT_NONE;
	const char *location, *pci_str, *drv_str, *bus_pci_str, *bus_drv_str;

	frozen_dn = eeh_find_device_pe(eeh_dev_to_of_node(event->edev));
	if (!frozen_dn) {
		location = of_get_property(eeh_dev_to_of_node(event->edev), "ibm,loc-code", NULL);
		location = location ? location : "unknown";
		printk(KERN_ERR "EEH: Error: Cannot find partition endpoint "
		                "for location=%s pci addr=%s\n",
			location, eeh_pci_name(eeh_dev_to_pci_dev(event->edev)));
		return NULL;
	}

	frozen_bus = pcibios_find_pci_bus(frozen_dn);
	location = of_get_property(frozen_dn, "ibm,loc-code", NULL);
	location = location ? location : "unknown";

	if (!frozen_bus)
		frozen_bus = pcibios_find_pci_bus(frozen_dn->parent);

	if (!frozen_bus) {
		printk(KERN_ERR "EEH: Cannot find PCI bus "
		        "for location=%s dn=%s\n",
		        location, frozen_dn->full_name);
		return NULL;
	}

	frozen_edev = of_node_to_eeh_dev(frozen_dn);
	frozen_edev->freeze_count++;
	pci_str = eeh_pci_name(eeh_dev_to_pci_dev(event->edev));
	drv_str = eeh_pcid_name(eeh_dev_to_pci_dev(event->edev));

	if (frozen_edev->freeze_count > EEH_MAX_ALLOWED_FREEZES)
		goto excess_failures;

	printk(KERN_WARNING
	   "EEH: This PCI device has failed %d times in the last hour:\n",
		frozen_edev->freeze_count);

	if (frozen_edev->pdev) {
		bus_pci_str = pci_name(frozen_edev->pdev);
		bus_drv_str = eeh_pcid_name(frozen_edev->pdev);
		printk(KERN_WARNING
			"EEH: Bus location=%s driver=%s pci addr=%s\n",
			location, bus_drv_str, bus_pci_str);
	}

	printk(KERN_WARNING
		"EEH: Device location=%s driver=%s pci addr=%s\n",
		location, drv_str, pci_str);

	pci_walk_bus(frozen_bus, eeh_report_error, &result);

	rc = eeh_ops->wait_state(eeh_dev_to_of_node(frozen_edev), MAX_WAIT_FOR_RECOVERY*1000);
	if (rc < 0 || rc == EEH_STATE_NOT_SUPPORT) {
		printk(KERN_WARNING "EEH: Permanent failure\n");
		goto hard_fail;
	}

	eeh_slot_error_detail(frozen_edev, EEH_LOG_TEMP);

	if (result == PCI_ERS_RESULT_NONE) {
		rc = eeh_reset_device(frozen_edev, frozen_bus);
		if (rc) {
			printk(KERN_WARNING "EEH: Unable to reset, rc=%d\n", rc);
			goto hard_fail;
		}
	}

	
	if (result == PCI_ERS_RESULT_CAN_RECOVER) {
		rc = eeh_pci_enable(frozen_edev, EEH_OPT_THAW_MMIO);

		if (rc < 0)
			goto hard_fail;
		if (rc) {
			result = PCI_ERS_RESULT_NEED_RESET;
		} else {
			result = PCI_ERS_RESULT_NONE;
			pci_walk_bus(frozen_bus, eeh_report_mmio_enabled, &result);
		}
	}

	
	if (result == PCI_ERS_RESULT_CAN_RECOVER) {
		rc = eeh_pci_enable(frozen_edev, EEH_OPT_THAW_DMA);

		if (rc < 0)
			goto hard_fail;
		if (rc)
			result = PCI_ERS_RESULT_NEED_RESET;
		else
			result = PCI_ERS_RESULT_RECOVERED;
	}

	
	if (result == PCI_ERS_RESULT_DISCONNECT) {
		printk(KERN_WARNING "EEH: Device driver gave up\n");
		goto hard_fail;
	}

	
	if (result == PCI_ERS_RESULT_NEED_RESET) {
		rc = eeh_reset_device(frozen_edev, NULL);
		if (rc) {
			printk(KERN_WARNING "EEH: Cannot reset, rc=%d\n", rc);
			goto hard_fail;
		}
		result = PCI_ERS_RESULT_NONE;
		pci_walk_bus(frozen_bus, eeh_report_reset, &result);
	}

	
	if ((result != PCI_ERS_RESULT_RECOVERED) &&
	    (result != PCI_ERS_RESULT_NONE)) {
		printk(KERN_WARNING "EEH: Not recovered\n");
		goto hard_fail;
	}

	
	pci_walk_bus(frozen_bus, eeh_report_resume, NULL);

	return frozen_edev;
	
excess_failures:
	printk(KERN_ERR
	   "EEH: PCI device at location=%s driver=%s pci addr=%s\n"
		"has failed %d times in the last hour "
		"and has been permanently disabled.\n"
		"Please try reseating this device or replacing it.\n",
		location, drv_str, pci_str, frozen_edev->freeze_count);
	goto perm_error;

hard_fail:
	printk(KERN_ERR
	   "EEH: Unable to recover from failure of PCI device "
	   "at location=%s driver=%s pci addr=%s\n"
	   "Please try reseating this device or replacing it.\n",
		location, drv_str, pci_str);

perm_error:
	eeh_slot_error_detail(frozen_edev, EEH_LOG_PERM);

	
	pci_walk_bus(frozen_bus, eeh_report_failure, NULL);

	
	pcibios_remove_pci_devices(frozen_bus);

	return NULL;
}
示例#5
0
/**
 * eeh_handle_event - Reset a PCI device after hard lockup.
 * @event: EEH event
 *
 * While PHB detects address or data parity errors on particular PCI
 * slot, the associated PE will be frozen. Besides, DMA's occurring
 * to wild addresses (which usually happen due to bugs in device
 * drivers or in PCI adapter firmware) can cause EEH error. #SERR,
 * #PERR or other misc PCI-related errors also can trigger EEH errors.
 *
 * Recovery process consists of unplugging the device driver (which
 * generated hotplug events to userspace), then issuing a PCI #RST to
 * the device, then reconfiguring the PCI config space for all bridges
 * & devices under this slot, and then finally restarting the device
 * drivers (which cause a second set of hotplug events to go out to
 * userspace).
 */
struct eeh_dev *handle_eeh_events(struct eeh_event *event)
{
	struct device_node *frozen_dn;
	struct eeh_dev *frozen_edev;
	struct pci_bus *frozen_bus;
	int rc = 0;
	enum pci_ers_result result = PCI_ERS_RESULT_NONE;
	const char *location, *pci_str, *drv_str, *bus_pci_str, *bus_drv_str;

	frozen_dn = eeh_find_device_pe(eeh_dev_to_of_node(event->edev));
	if (!frozen_dn) {
		location = of_get_property(eeh_dev_to_of_node(event->edev), "ibm,loc-code", NULL);
		location = location ? location : "unknown";
		printk(KERN_ERR "EEH: Error: Cannot find partition endpoint "
		                "for location=%s pci addr=%s\n",
			location, eeh_pci_name(eeh_dev_to_pci_dev(event->edev)));
		return NULL;
	}

	frozen_bus = pcibios_find_pci_bus(frozen_dn);
	location = of_get_property(frozen_dn, "ibm,loc-code", NULL);
	location = location ? location : "unknown";

	/* There are two different styles for coming up with the PE.
	 * In the old style, it was the highest EEH-capable device
	 * which was always an EADS pci bridge.  In the new style,
	 * there might not be any EADS bridges, and even when there are,
	 * the firmware marks them as "EEH incapable". So another
	 * two-step is needed to find the pci bus..
	 */
	if (!frozen_bus)
		frozen_bus = pcibios_find_pci_bus(frozen_dn->parent);

	if (!frozen_bus) {
		printk(KERN_ERR "EEH: Cannot find PCI bus "
		        "for location=%s dn=%s\n",
		        location, frozen_dn->full_name);
		return NULL;
	}

	frozen_edev = of_node_to_eeh_dev(frozen_dn);
	frozen_edev->freeze_count++;
	pci_str = eeh_pci_name(eeh_dev_to_pci_dev(event->edev));
	drv_str = eeh_pcid_name(eeh_dev_to_pci_dev(event->edev));

	if (frozen_edev->freeze_count > EEH_MAX_ALLOWED_FREEZES)
		goto excess_failures;

	printk(KERN_WARNING
	   "EEH: This PCI device has failed %d times in the last hour:\n",
		frozen_edev->freeze_count);

	if (frozen_edev->pdev) {
		bus_pci_str = pci_name(frozen_edev->pdev);
		bus_drv_str = eeh_pcid_name(frozen_edev->pdev);
		printk(KERN_WARNING
			"EEH: Bus location=%s driver=%s pci addr=%s\n",
			location, bus_drv_str, bus_pci_str);
	}

	printk(KERN_WARNING
		"EEH: Device location=%s driver=%s pci addr=%s\n",
		location, drv_str, pci_str);

	/* Walk the various device drivers attached to this slot through
	 * a reset sequence, giving each an opportunity to do what it needs
	 * to accomplish the reset.  Each child gets a report of the
	 * status ... if any child can't handle the reset, then the entire
	 * slot is dlpar removed and added.
	 */
	pci_walk_bus(frozen_bus, eeh_report_error, &result);

	/* Get the current PCI slot state. This can take a long time,
	 * sometimes over 3 seconds for certain systems.
	 */
	rc = eeh_ops->wait_state(eeh_dev_to_of_node(frozen_edev), MAX_WAIT_FOR_RECOVERY*1000);
	if (rc < 0 || rc == EEH_STATE_NOT_SUPPORT) {
		printk(KERN_WARNING "EEH: Permanent failure\n");
		goto hard_fail;
	}

	/* Since rtas may enable MMIO when posting the error log,
	 * don't post the error log until after all dev drivers
	 * have been informed.
	 */
	eeh_slot_error_detail(frozen_edev, EEH_LOG_TEMP);

	/* If all device drivers were EEH-unaware, then shut
	 * down all of the device drivers, and hope they
	 * go down willingly, without panicing the system.
	 */
	if (result == PCI_ERS_RESULT_NONE) {
		rc = eeh_reset_device(frozen_edev, frozen_bus);
		if (rc) {
			printk(KERN_WARNING "EEH: Unable to reset, rc=%d\n", rc);
			goto hard_fail;
		}
	}

	/* If all devices reported they can proceed, then re-enable MMIO */
	if (result == PCI_ERS_RESULT_CAN_RECOVER) {
		rc = eeh_pci_enable(frozen_edev, EEH_OPT_THAW_MMIO);

		if (rc < 0)
			goto hard_fail;
		if (rc) {
			result = PCI_ERS_RESULT_NEED_RESET;
		} else {
			result = PCI_ERS_RESULT_NONE;
			pci_walk_bus(frozen_bus, eeh_report_mmio_enabled, &result);
		}
	}

	/* If all devices reported they can proceed, then re-enable DMA */
	if (result == PCI_ERS_RESULT_CAN_RECOVER) {
		rc = eeh_pci_enable(frozen_edev, EEH_OPT_THAW_DMA);

		if (rc < 0)
			goto hard_fail;
		if (rc)
			result = PCI_ERS_RESULT_NEED_RESET;
		else
			result = PCI_ERS_RESULT_RECOVERED;
	}

	/* If any device has a hard failure, then shut off everything. */
	if (result == PCI_ERS_RESULT_DISCONNECT) {
		printk(KERN_WARNING "EEH: Device driver gave up\n");
		goto hard_fail;
	}

	/* If any device called out for a reset, then reset the slot */
	if (result == PCI_ERS_RESULT_NEED_RESET) {
		rc = eeh_reset_device(frozen_edev, NULL);
		if (rc) {
			printk(KERN_WARNING "EEH: Cannot reset, rc=%d\n", rc);
			goto hard_fail;
		}
		result = PCI_ERS_RESULT_NONE;
		pci_walk_bus(frozen_bus, eeh_report_reset, &result);
	}

	/* All devices should claim they have recovered by now. */
	if ((result != PCI_ERS_RESULT_RECOVERED) &&
	    (result != PCI_ERS_RESULT_NONE)) {
		printk(KERN_WARNING "EEH: Not recovered\n");
		goto hard_fail;
	}

	/* Tell all device drivers that they can resume operations */
	pci_walk_bus(frozen_bus, eeh_report_resume, NULL);

	return frozen_edev;
	
excess_failures:
	/*
	 * About 90% of all real-life EEH failures in the field
	 * are due to poorly seated PCI cards. Only 10% or so are
	 * due to actual, failed cards.
	 */
	printk(KERN_ERR
	   "EEH: PCI device at location=%s driver=%s pci addr=%s\n"
		"has failed %d times in the last hour "
		"and has been permanently disabled.\n"
		"Please try reseating this device or replacing it.\n",
		location, drv_str, pci_str, frozen_edev->freeze_count);
	goto perm_error;

hard_fail:
	printk(KERN_ERR
	   "EEH: Unable to recover from failure of PCI device "
	   "at location=%s driver=%s pci addr=%s\n"
	   "Please try reseating this device or replacing it.\n",
		location, drv_str, pci_str);

perm_error:
	eeh_slot_error_detail(frozen_edev, EEH_LOG_PERM);

	/* Notify all devices that they're about to go down. */
	pci_walk_bus(frozen_bus, eeh_report_failure, NULL);

	/* Shut down the device drivers for good. */
	pcibios_remove_pci_devices(frozen_bus);

	return NULL;
}